EasyManua.ls Logo

GW Instek ASR-2000 Series - [:Source]:Frequency:limit:low; [:Source]:Frequency[:Immediate]

GW Instek ASR-2000 Series
125 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ASR-2000 Programming Manual
80
Syntax
[:SOURce]:FREQuency:LIMit:HIGH
{<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:FREQuency:LIMit:HIGH?
[INimum|MAXimum]
Parameter
<NR2>
Frequency in Hz.
MINimum
Minimum settable frequency
MAXimum
Maximum settable frequency
Return parameter
<NR2>
Returns the frequency limit
Example
FREQ:LIM:HIGH?
>60.50
Returns the frequency upper limit.
[:SOURce]:FREQuency:LIMit:LOW
Set
Query
Description
Sets or queries the frequency lower limit range.
(Only AC+DC-INT or AC-INT or AC+DC-ADD or
AC-ADD Active)
Syntax
[:SOURce]:FREQuency:LIMit:LOW
{<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:FREQuency:LIMit:LOW?
[INimum|MAXimum]
Parameter
<NR2>
Frequency in Hz.
MINimum
Minimum settable frequency
MAXimum
Maximum settable frequency
Return parameter
<NR2>
Returns the frequency limit
Example
FREQ:LIM:LOW?
>60.50
Returns the frequency lower limit.
[:SOURce]:FREQuency[:IMMediate]
Set
Query
Description
Sets or queries the frequency for the immediate
trigger. (Only AC+DC-INT or AC-INT or AC+DC-
ADD or AC-ADD Active)

Table of Contents