Page #70 background image
ASR-2000 Programming Manual
70
Parameter/Return
parameter
LOCal
All keys are valid. This instrument is
controlled by the front panel controls.
REMote
All keys are invalid, except for the [local] key
and the ability to turn the output off.
RWLock
All keys are invalid. The instrument can only
be controlled remotely.
LREMote
All keys are valid. This instrument is
controlled by the front panel controls and
remotely.
Example
:SYST:COMM:RLST LOCAL
Sets the operating mode to local.
:SYSTem:COMMunicate:SERial[:RECeive]
:TRANsmit:BAUD
Set
Query
Description
Sets or queries the UART baud rate.
Note:
The setting will only be valid after the power has
been cycled.
Syntax
Query Syntax
:SYSTem:COMMunicate:SERial[:RECeive]:TRANsmit
:BAUD <NR1>
:SYSTem:COMMunicate:SERial[:RECeive]:TRANsmit
:BAUD?
Parameter/Return
<NR1>
1200, 2400, 4800, 9600, 19200, 38400,
57600, 115200
Example
SYST:COMM:SER:TRAN:BAUD?
>2400
Returns the baud rate settings.
:SYSTem:COMMunicate:SERial[:RECeive]
:TRANsmit:BITS
Set
Query
Description
Sets or queries the UART number of data bits.
Note:
The setting will only be valid after the power has
been cycled.

Table of Contents

Other manuals for GW Instek ASR-2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek ASR-2000 Series and is the answer not in the manual?

GW Instek ASR-2000 Series Specifications

General IconGeneral
BrandGW Instek
ModelASR-2000 Series
CategoryPortable Generator
LanguageEnglish

Related product manuals