REMOTE CONTROL
97
[:SOURce]:SIMulation:ABNormal:TIME
Sets or queries the Time parameter of the abnormal
step for the Simulation mode.
[:SOURce]:SIMulation:ABNormal:TIME
{<NR2>|MINimum|MAXimum}
[:SOURce]:SIMulation:ABNormal:TIME?
[MINimum|MAXimum]
Parameter/Return
parameter
Time of the abnormal step in seconds
:SIM:ABN:TIME 1
Sets the abnormal step time to 1 second.
[:SOURce]:SIMulation:ABNormal:VOLTage
Sets or queries the Vset parameter of the abnormal
step for the Simulation mode.
[:SOURce]:SIMulation:ABNormal:VOLTage
{<NR2>|MINimum|MAXimum}
[:SOURce]:SIMulation:ABNormal:VOLTage?
[MINimum|MAXimum]
Parameter/Return
parameter
Voltage of the abnormal step.
:SIM:ABN:VOLT MAX
Sets the abnormal step voltage to the maximum.
[:SOURce]:SIMulation:CSTep
Returns the currently running step.
[:SOURce]:SIMulation:CSTep?