136
Remote Sense
The remote sense function detects the output voltage at the sensing
input terminal. This function compensates for voltage drops across
the load cables when the load is connected to the ASR-3000 over a
long distance.
The remote sense function can compensate a
maximum of 5% of the output voltage. The
maximum output voltage when compensation is
used is limited by the rated voltage.
1. Press the Menu key. The Menu
setting will appear on the display.
2. Use the scroll wheel to go to item 2, MISC
Configuration and press Enter.
3. Go to the Remote Sense setting using the scroll
wheel and press Enter. Turn the setting on or
off and press Enter again to confirm.
Remote Sense
ON, OFF
4. Press Exit[F4] to exit from the
MISC Configuration settings.
Remote Sense setting