Video Security Control Panel User Manual
{1} The programming command address of print setting of restoring information of alarm and bypass is:
503;
{2} Sensor Alarm Recovering;
{3} Bypass Recovering;
{4} End the command.
Device Recovering Information Settings 3.1.21
The programming commands of print setting of device recovering information are as below:
504 0 0 0 0 0 0 0 #
1 2
4
6
3
5
7
8
9
{1} The programming command address of print setting of device recovering information is: 504;
{2} AC power on;
{3} The storage battery is not under voltage;
{4} Reserved, enter 0;
{5} The tamper-proof of the control panel is recovered;
{6} The 485 device is on-line;
{7} The network error is recovered;
{8} The GPRS exception is recovered.
It indicates disabled status when 2) ~8) are set to be 0, and indicates enabled status when 2) ~8) are set to be 1.
{9} End of command.