The me interval between two connuous face recognions when authencang. By
default, it is 2s.
Face An-spoong
Enable or disable the live face detecon funcon. If enabling the funcon, the device
can recognize whether the person is a live one or not.
Face 1:1 Matching Threshold
Set the matching threshold when authencang via 1:1 matching mode. The larger the
value, the smaller the false accept rate and the larger the false
rejecon rate when
authencaon.
Applicaon Mode
You can select indoor or others applicaon modes according to actual environment.
Lock Authencaon Failed Face
Aer enabling the Live Face Detecon funcon, the system will lock the user's face for
5 minutes if the live face
detecon is failed for more than the congured aempts. The
same user cannot authencate via the fake face within 5 minutes. Within the 5
minutes, the user can authencate via the real face twice connuously to unlock.
Liveness Detecon Security Level
Aer enabling Live Face Detecon funcon, you can set the matching security level
when performing live face authencaon.
4. Click OK.
5.
Oponal: Click Copy to, and then select the card reader(s) to copy the parameters in the page
to the selected card reader(s).
Congure
Parameters for Alarm Output
Aer adding the access control device, if the device links to alarm outputs, you can congure the
parameters.
Before You Start
Add access control device to the client, and make sure the device supports alarm output.
Steps
1. Click Access Control → Advanced
Funcon → Device Parameter to enter access control
parameter conguraon page.
2. In the device list on the
le, click to expand the door, select an alarm input and you can edit
the alarm input's parameters on the right.
3. Set the alarm output parameters.
Name
Edit the card reader name as desired.
Alarm Output
Acve Time
Face Recognion Terminal User Manual