MP blade name MP blade number MP blade ID
MPB-2PL 14 14
MPB-2PM 15 15
Table 3-8 MP blade names and parameters for VSP
MP blade name MP blade number MP blade ID
MPB-1MA 0 0
MPB-1MB 1 1
MPB-2MC 2 2
MPB-2MD 3 3
MPB-1ME 4 4
MPB-1MF 5 5
MPB-2MG 6 6
MPB-2MH 7 7
Table 3-9 MP unit names and parameters for HUS VM
MP unit name MP blade number MP blade ID
MPU-10 0 0
MPU-11 1 1
MPU-20 2 2
MPU-21 3 3
LDEV grouping function
The LDEV grouping function enables you to create a group of multiple LDEVs
(device group function and copy group function).
Overview
CCI can be used to create a group of multiple LDEVs by defining copy groups,
which are a group of copy pairs. This is accomplished in both the primary and
secondary configuration definition files by defining the group names of the
combined LDEVs (dev_name of HORCM_DEV or HORCM_LDEV).
To change copy group information, modify the primary and secondary
configuration definition files. For example, to change the LDEV configuration
of copy group dbA (see following figure), change the LDEV information in
configuration definition files A and B.
CCI functions
3-35
Command Control Interface User and Reference Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi VSP F1500 and is the answer not in the manual?

Hitachi VSP F1500 Specifications

General IconGeneral
BrandHitachi
ModelVSP F1500
CategoryServer
LanguageEnglish

Related product manuals