Problem Recommended action
HORCM_LOG (the default setting: /horcm/log/), and then contact
Hitachi Data Systems customer support.
The following
messages are
output to the
standard error
output with
every command
I/O:
"/usr/lib/
dld.sl: Can't
shl_load() a
library
containing
Thread Local
Storage: /usr/
lib/libcl.sl"
"/usr/lib/
dld.sl: Exec
format error"
These messages are output if the path for the PA-RISC version shared
library (libcl.sl) is not set when you use CCI on HP-UX (IA64).
Set the path of the libcl.sl to the LD_PRELOAD environment variable.
Example: # export LD_PRELOAD=/path/libcl.sl
Enter the absolute path for specifying the directory where libcl.sl is
stored into path.
When you
attempt to
remove RM
Shadow Copy
Provider, the
installer displays
a message
indicating that a
file cannot be
deleted because
it is used by
another
program.
Perform the following steps to delete the file:
1. Check the information about the program that is using the file
indicated by the installer.
2. Stop the removal of RM Shadow Copy Provider.
3. Close the program you found out in step 1.
4. Try to remove RM Shadow Copy Provider again.
5. Repeat steps 1 through 4 until you can remove RM Shadow Copy
Provider successfully.
Operational notes and restrictions for CCI operations
For maintenance of volumes used by CCI and the HDS features it supports, if
a volume failure occurs, it is important to find the failure in the paired
volumes, recover the volumes, and continue operation on the original
system. When a CCI (HORCM) or HDS feature failure is detected, please
collect the data in the error log file and trace data (all files in HORCM_LOG
directory), and report the failure to your HDS representative.
Items Notes and restrictions
Startup restrictions When the server starts up, sometimes a volume group (VG) is
activated by the LVM, or a file system is mounted automatically,
and the host writes to the S-VOL. When this happens, if the S-VOL
does not permit writing, data cannot be written and the operation
fails. To avoid this failure, change the S-VOL to PSUS (R/W enable)
or to the SMPL state and restart the server.
Troubleshooting
9-3
Command Control Interface User and Reference Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi VSP F1500 and is the answer not in the manual?

Hitachi VSP F1500 Specifications

General IconGeneral
BrandHitachi
ModelVSP F1500
CategoryServer
LanguageEnglish

Related product manuals