OTHER ELECTRICAL
FUSE INSPECTION
Remove the blade type fuse (page 11-4).
Visually inspect the fuse to see if it is blown. Check
continuity across the two blades. Replace the fuse if it is
blown or there is no continuity across the blades.
REGULATOR/RECTIFIER INSPECTION
Measure the resistance between the terminals and be
sure that the measurements conform to the ranges
shown in the table.
10A TYPE
18A TYPE
Use a tester that is equivalent to or higher than the
performance specified, internal resistance: 20 kȍ/VDC,
9 kȍ/VAC
Be careful not to touch the metallic part of the tester
probe with your fingers; otherwise, the correct
resistance value cannot be obtained.
Read the tester manufacturer‘s operation instructions
carefully before operating the tester. Follow the
instructions of the Service Manual. Be sure the tester‘s
battery is fully charged, and check the meter before
using the tester.
BLOWN
Unit: kȍ
4 6 1 3
4
6
1 1 - 200 1 - 200 0.5 - 100
3 0.1 - 50 0.1 - 50
Not used
4
6
3
1
Unit: kȍ
4 6 1 2 3
4 4 - 400 2 - 230
6 4 - 400 2 - 230
1
2 2 - 230 2 - 230 1 - 600
3 0.09 -
400
0.09 -
400
Not used
4
6
3
1
2