EasyManuals Logo
Home>Honeywell>Safes>5110

Honeywell 5110 User Manual

Honeywell 5110
199 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #155 background imageLoading...
Page #155 background image
11 - 3
Examples of Query Commands
In the following examples, a bracketed notation [ ] depicts a non-displayable
response.
Example: Example #1:What is the range of possible values for Codabar
Coding Enable?
Enter: cbrena*.
Response: CBRENA0-1[ACK]
This response indicates that Codabar Coding Enable (CBRENA) has a range of
values from 0 to 1 (off and on).
Example: Example #2: What is the default value for Codabar Coding Enable?
Enter: cbrena^.
Response: CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding Enable
(CBRENA) is 1, or on.
Example: Example #3: What is the device’s current setting for Codabar
Coding Enable?
Enter: cbrena?.
Response: CBRENA1[ACK]
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on.
Example: Example #4: What are the device’s settings for all Codabar
selections?
Enter: cbr?.
Response: CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.

Table of Contents

Other manuals for Honeywell 5110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell 5110 and is the answer not in the manual?

Honeywell 5110 Specifications

General IconGeneral
BrandHoneywell
Model5110
CategorySafes
LanguageEnglish

Related product manuals