4 - 6
User-Specified Good Read Delay
If you want to set your own length for the good read delay, scan the bar code
below, then set the delay (from 0-30,000 milliseconds) by scanning digits from
the inside back cover, then scanning
Save
.
Trigger Modes
Manual/Serial Trigger
You can activate the imager either by providing an external hardware trigger, or
using a serial trigger command (see Trigger Commands on page 11-4). When
in manual trigger mode, the imager scans until a bar code is read, or until the
hardware trigger is released.
When in serial mode, the imager scans until a bar code has been read or until
the deactivate command is sent. In serial mode, the imager can also be set to
turn itself off after a specified time has elapsed (see Read Time-Out, which
follows).
Read Time-Out
Use this selection to set a time-out (in milliseconds) of the imager’s trigger when
using serial commands to trigger the imager, or if the imager is in manual trigger
mode. Once the imager has timed out, you can activate the imager either by
pressing the trigger or using a serial trigger command. After scanning the
Read
Time-Out
bar code, set the time-out duration (from 0-300,000 milliseconds) by
scanning digits from the inside back cover, then scanning
Save
.
Default = 0
(infinite, or no time-out).
User-Specified Good Read Delay