4 - 5
Beep Polarity
Beep Polarity sets the idle and active states of the beeper signal. When set to
Active High
, the beeper sounds when the signal shifts from low to high. When
set to
Active Low
, the beeper sounds when the signal shifts from high to low.
If the beeper is enabled for a good read (see Beeper – Good Read on page 4-
1), the polarity change takes effect after the next successful decode or a power
cycle. If the beeper is disabled, a polarity change only takes effect after a power
cycle.
Default = Active Low.
Note: Beep Polarity sets the beeper signal voltage level to either high (Active
Low) or low (Active High). This will affect Beeper-Good Read settings. If
the beeper has been disabled, make sure it is not turned on accidentally
by a polarity change.
Good Read Delay
This sets the minimum amount of time before the imager can read another bar
code.
Default = No Delay.
* No Delay
Short Delay (500 ms)
Medium Delay (1,000 ms)
Long Delay (1,500 ms)