Page #122 background imageLoading...
Page #122 background image
Model
1630A/D/G

Using
HP-I13 or
HP-IL
Interface
TE
-
Transmit
Everything
Learn
String
The
transmit
everything
learn
string
command
instructs
the
analyzer
to
transmit
the
following data
in
the
listed
sequence
:
(1
)
configuration
learn
string,
(2)
state
data
acquisition
learn
string,
and
(3)
timing
data
acquisition
learn
string
.
Refer
to
the
TC, TS,
and
TT
command
descriptions
for
learn
string
formats
.
The
maximum
number
of
bytes
will
be
the
sum
of
the
bytes
of
the
individual
commands
.
The
maximum
number
of
bytes
(4284)
will
occur
in
the
combined
State/Timing
Mode
.
DATA
TRANSFER
TERMINATION
Binary
transfers
of
data
are
terminated
by
setting
EOI
true
with
the
last
byte
transferred
.
Non-binary
transfers
are
terminated
by
sending
CR
LF
with
EOI
true
.
HP1630G
LEARN
STRING
COMMANDS
TC
-
Transmit
Configuration
Learn
String
The
transmit configuration
learn
string
command
causes
the
HP
1630G
analyzer
to
transmit
a
string
containing
its
configuration
data
plus
two
CRC
bytes
.
HP
1630G
Learn
String
Format
for
Transmit
Configuration
NOTE
The
binary
value
of
these
bytes
is
the
number
of
bytes
to follow
including
the
CRC
bytes
.
This
value
is
transmitted
as
MSB
first
and
LSB
last
.
Thenumber
of
bytes
transmitted
is
5476
.
TS
-
Transmit
State
Acquisition
Learn
String
The
transmit
state
acquisition
learn
string
command
causes
the
HP
1630G
analyzer
to
transmit
a
string
containing
its
state
measurement
data
plus
two
CRC
bytes
.
The
measurement
data
consists
of
state
trace
data,
state label
overview
data,
time
interval
overview
data,
time
positional
data,
or
linkage
overview
data
.
The
actual
state
data
(trace,
label
overview,
time
interval,
time
positional,
or
linkage
overview)
is
transmitted
in
the following
manner
.
The
first
seven
bits
of
the
MSB
are
internal
.
The
last
two
least
significant
bits
of
the
MSB
correspond
to
data
from
Pod
7
bit
9,
etc
.,
as
shown
below
.
9-
1
5
SYNTAX
:
TC
;
Starting
Byte
Number
Position
Of
In
String
Bytes
Contents
1
2
(A)
RC
(Receive
Configuration
Command)
3 2
(I)
Binary
byte
count
(refer
to
Note)
CRC
STARTS
ACCUMULATING
WITHNEXTBYTE
5
5476
Configuration
Data
CRC
STOPPED
ACCUMULATING
WITHPREVIOUSBYTE
5476
1
Revision
Code
5477
2
(I)
CRC
bytes

Table of Contents

Other manuals for HP 1630D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 1630D and is the answer not in the manual?

HP 1630D Specifications

General IconGeneral
BrandHP
Model1630D
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals