Fabric OS 6.2 administrator guide 529
6. Reenable the switches in the updated fabric one at a time. In a core/edge network, enable the core
switches first.
7. After the fabric has reconverged, use the cfgEnable command to update zoning.
8. Bring the devices online in the order appropriate to the SAN. This usually involves starting up the
storage arrays first, and the hosts last.
9. For any devices manually bound by PID, bring the device back online, but do not start applications.
Update their bindings and reboot again if necessary. This might involve changing them to the new
PIDs, or might (preferably) involve changing to WWN binding.
10. For any devices automatically bound by PID, reboot the device to rebuild the device tree (some
operating systems require a special command to do this, such as “boot –r” in Solaris).
11. For devices that do not bind by PID or have had their PID binding updated, bring them back up and
resume I/O.
12. Verify that all I/O has resumed correctly.
Hybrid update
It is possible to combine the online and offline methods for fabrics where only a few devices bind by PID.
Because any hybrid procedure is extremely customized, it is necessary to work closely with the SAN service
provider in these cases.
Changing to core PID format
In Fabric OS release 4.2.0 and later, Native PID format is not supported; the default format is the Core PID
format.
In Fabric OS 3.1.2 and later, Core PID format is the default configuration.
Although the PID format is listed in the configuration file, do not edit the file to change the setting there.
Instead, use the configure command in Fabric OS 6.0.0 and earlier. When you use the configure
command, switch databases that contain PID-sensitive information are automatically updated. If you
change the setting in the configuration file and then download the edited file, the PID format will be
changed, but the database entries will not, and so they will be incorrect.
The following list maps the PID format names to the switch PID address modes used in the management
interfaces:
Native PID—Switch PID address mode 0
Core PID—Switch PID address mode 1
Extended edge PID—Switch PID address mode 2

Table of Contents

Other manuals for HP StorageWorks 4/8 - SAN Switch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 4/8 - SAN Switch and is the answer not in the manual?

HP StorageWorks 4/8 - SAN Switch Specifications

General IconGeneral
BrandHP
ModelStorageWorks 4/8 - SAN Switch
CategorySwitch
LanguageEnglish

Related product manuals