5.22 Mainboard
● There are two types of mainboards: mainboard for the server with Kunpeng
920 7260, 5250, or 5230 processors and mainboard for the server with Kunpeng
920 5220 or 3210 processors. Before replacing the mainboard, obtain the spare
part based on the processor model. For details about how to query the server
model, see 8.7 Querying the Processor Model of a Server.
● This section uses the server with Kunpeng 920 7260, 5250, or 5230 processors
as an example to describe the internal structure of a server. The procedures for
removing and installing the mainboard are the same for the server
congured
with Kunpeng 920 5220 or 3210 processors.
Removing the Mainboard
Step 1 Conrm the iBMC and BIOS congurations with the customer for quick recovery
after replacing the mainboard.
Step 2 Log in to the iBMC and record iBMC, BIOS, and CPLD rmware versions of the
mainboard to be replaced. (Choose Information > System Info > Product Info >
Mainboard Info on the iBMC WebUI or run the ipmcget -d version command on
the iBMC CLI.)
Step 3 (Optional) Export the iBMC and BIOS
conguration les. For details, see "Import/
Export" in the
TaiShan Rack Server iBMC User Guide
. After replacing the
mainboard, you can quickly restore the server conguration by importing the
iBMC and BIOS conguration les.
● The iBMC and BIOS conguration les exported from the iBMC can be directly imported
after the mainboard replacement. However, the exported conguration les do not
contain password information. You need to manually congure the password for the
iBMC user. For details, see "Import/Export" in the
TaiShan Rack Server iBMC User
Guide
.
● If the iBMC of the mainboard to be replaced cannot be logged in or the iBMC and BIOS
conguration les are not exported before the mainboard is replaced, you need to
manually congure the iBMC and BIOS after replacing the mainboard.
Step 4 Wear an ESD wrist strap. For details, see 5.2 ESD Protection.
Step 5 Power o the server. For details, see 5.4.2 Powering O the Server.
Step 6 Remove the power cables. For details, see 5.7 PSU.
Step 7 Remove the server. For details, see 5.4.4 Removing the Server and Guide Rails.
Step 8 Remove the FlexIOs. For details, see 5.17 FlexIO Card.
Step 9 Remove the chassis cover. For details, see 5.8 Chassis Cover.
Step 10 Remove the air duct. For details, see 5.9 Air Duct.
TaiShan 200 Server
Maintenance and Service Guide (Model 2280) 5 Removal and Installation
Issue 04 (2020-01-16) Copyright © Huawei Technologies Co., Ltd. 153