C.6 Recovery Function
The recovery function helps to set all device parameters to factory defaults after a fatal
system breakdown.
The recovery key is necessary to invoke the recovery procedure.
Picture 72: Recovery Key
A recovery key is delivered with every device,
it is marked with the label Recovery.
Important: The recovery function resets the IP address to the factory default value of
192.168.1.50. It may be necessary to use the crossover cable and change
the network settings on the local computer.
C.6.1 Important Notes Before Recovering to Factory Defaults
The steps described in the following should only be executed after a fatal system
breakdown!
Write down the values for the IP address, subnet mask and gateway of the device before
starting the recovery sequence.
After recovering to the factory default values, a firmware update has to be executed!
Make sure an update file is available on the local computer.
After recovering to the factory defaults, all adjustment procedures described in the
previous sections have to be executed again!
Setup and Assembly Manual Page 61

Table of Contents

Other manuals for Image Access WideTEK 36

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Image Access WideTEK 36 and is the answer not in the manual?

Image Access WideTEK 36 Specifications

General IconGeneral
BrandImage Access
ModelWideTEK 36
CategoryScanner
LanguageEnglish

Related product manuals