Setup and Assembly Manual Page 67
Error codes, part 3
Error
#
Error message shown in
the display
Error message sent to
application
Problem description
70 Error 70: ADC error camera 2 Camera 2 adc error. Test data transfer through analog digital
converter failed. Check cables /
connectors to camera 2.
71 Error 71: ADC error camera 3 Camera 3 adc error. Test data transfer through analog digital
converter failed. Check cables /
connectors to camera 3.
75 General keyboard error General keyboard error. Check keyboard
and cables.
82 Bad scan background
Please clear transport
Bad Scan background
Automatic measurement can not be
executed. Remove documents from the
transport section.
99 Internal error. The firmware has detected an internal
error of unknown cause.
C.8 Warnings
Warning
#
Warning shown in the
display
Warning sent to
application
Problem description
83 Scan background was
changed
Scan background was
changed
The background was changed. Repeat
scan sequence to correct the measured
value. Warning will disappear.
144 Light level is low
The light level is found to be low during
the white balance function.
145 Camera adjustment required Camera adjustment
required
General information about the camera
adjustment. Check for details and
readjust.
160 W160 NO WHITE BALANCE
DATA
No white balance data No white balance data was found.
Perform white balance.
180 Deskew failed The deskew function failed. Reposition
document.
181 Stitching2D: out of
memory. Using fixed
stitching
There is not enough memory available
to complete the stitching function.
182 Stitching2D: bad
matching. Using fixed
stitching
2D stitching can not deliver a matching
result. Switch to “Fixed” stitching.
C.9 Information
Infor-
mation
#
Information shown in the
display
Information sent to
application
Description
200 CREATING
RECOVERY PART..
Creating Recovery
Partition
While creating the recovery partition, the
scanner can not be accessed.

Table of Contents

Other manuals for Image Access WideTEK 36

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Image Access WideTEK 36 and is the answer not in the manual?

Image Access WideTEK 36 Specifications

General IconGeneral
BrandImage Access
ModelWideTEK 36
CategoryScanner
LanguageEnglish

Related product manuals