GENSET AND BATTERY PACK
4222983 Second Edition 3-39
3
WARNING
3. Disconnect the negative (–) battery cable (2) from
each battery.
4. Disconnect the positive (+) battery cable (1) from
each battery.
5. Remove screws (3), washers (4), lock washers (5),
nuts (6), and buffer battery pack cover (7).
6. Remove four 12V buffer batteries (8).
Figure 3-72
7. Remove three screws (9) and lock washers (10).
8. Remove screw (14), flat washer (13), lock washer
(12), and nut (11).
9. Remove buffer battery pack tray (15).
Installation Notes
• Install buffer battery pack and buffer battery pack tray
by reversing the order of removal.
• Route battery cables between the buffer battery pack
and the machine, avoiding pinch points.
Starter Battery
Removal and Installation
See Figure 3-73.
NOTE
The diesel model is shown; the gas model is similar.
WARNING
WARNING
1. Park the mower safely. (See “Park Mower Safely” on
page 1-6.)
Figure 3-73
NOTE
Label all wires before disconnecting to ensure correct
installation.
Always disconnect the negative terminal first and
positive terminal last. Connect positive terminal
first and negative terminal last. Use care when
testing live circuits to prevent arcing. Arcing
could result in death or serious injury.
TN2450
9
10
13
12
11
14
9
15
10
Be sure that the key switch is off, all electrical
accessories are turned off, and the 12-volt and
48-volt power connectors are disconnected
before starting work on vehicle.
• Battery posts, terminals, and related
accessories contain lead and lead
compounds. Wash your hands after handling.
• Always wear eye protection when servicing
battery.
1
2
7
5
TN2451
4 3
6