28
3. Adjusting the needle stop position
(1) Stop position after thread trimming
1) The standard needle stop position is obtained by
aligning pointer
A
on the machine arm with white
marker dot
B
on the handwheel.
2)
Stop the needle in its highest position, and loosen screw
1
to perform adjustment within the slot of the screw.
1
The needle stop timing is advanced if you move the
screw in direction
C
.
2
The needle stop timing is delayed if you move the
screw in direction
D
.
Do not operate the machine with screw
1
loosened. Just loosen the screw, and do
not remove it.
(2) Lower stop position
1)
The lower needle stop position when the pedal is returned
to the neutral position after the front part of the pedal is
depressed can be adjusted as follows : Stopneedle
1
in
its lowest position, loosen screw
2
, and make adjustment
within the slot of the screw. Moving the screw in direction
A
advances the needle stop timing. Moving the screw in
direction
B
delays the timing.
Do not operate the machine with screw
2
loosened. Just loosen the screw, and do
not remove it.
WARNING :
To protect against possible personal injury due to abrupt start of the machine, be sure to start the
following work after turning the power off and ascertaining that the motor is at rest.
1
B
C
A
D
1
2
A
B

Table of Contents

Other manuals for JUKI DLN-6390

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JUKI DLN-6390 and is the answer not in the manual?

JUKI DLN-6390 Specifications

General IconGeneral
BrandJUKI
ModelDLN-6390
CategorySewing Machine
LanguageEnglish

Related product manuals