99
11.14 EN
6.2 Preparing the truck for operation
Before starting the truck
Z The truck should only be operated from the driver’s seat. Do not run up the engine
in idle. The engine soon reaches operating temperature at a moderate charge and
when the speed alternates. Only fully charge the engine once it has reached
operating temperature.
Requirements
– Checks and operations to be performed before starting daily operation, see
"Checks and operations to be performed before starting daily operation" on
page 86.
Switching On the Truck
Procedure
• Turn the battery isolator (182) to position "1".
• Unlock the Emergency Disconnect (89),
• Turn the rotary button until the switch unlocks.
• Set the travel direction switch to neutral position
N.
• Parking brake is activated.
• Carry out the appropriate starting procedure for
the engine type; see 6.2.1 "Starting procedure for
the DFG" or 6.2.2 "Starting procedure for the
TFG".