EasyManuals Logo
Home>KEB>Servo Drives>COMBIVERT S6

KEB COMBIVERT S6 User Manual

KEB COMBIVERT S6
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
3.3.9 Fan
Unit size 12 13 14
Heat sink fan
Number 1
Speed-variable
Table 22: Fan
NOTICE
Destruction of the fan!
Take care that no foreign substances drop into the fan!
3.3.9.1 Switching behaviour of the fan
The fan has different switch-on and switch-off points. The switching point for the switch-
on temperature of the fan is adjustable. The switching point for the switch-off temper-
ature cannotbechangedandisalways5°Cbelowtheswitch-ontemperature.
0
20
40
60
80
100
0 20 40 6050 70 9080 100
3010
Temperature/°C
Fan speed / %
Legend
Temperature curve
Setting range for the switch-on temperature
Switch-on point
Switch-off point
Figure 8: Switching behaviour of the fan
3.3.9.2 Switching points of the fan
The switching point for the switch-on temperature is adjustable between 0.1°C and
50°C.Thedefaultvalueis50°C.
39
UNIT DATA

Table of Contents

Other manuals for KEB COMBIVERT S6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT S6 and is the answer not in the manual?

KEB COMBIVERT S6 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT S6
CategoryServo Drives
LanguageEnglish

Related product manuals