Command Reference B-3
Miscellaneous commands
Miscellaneous commands are those commands that perform such functions as saving calibra-
tion constants, locking out calibration, and programming date parameters.
:CODE
(:CALibration:PROTected:CODE)
Purpose To unlock calibration so you can perform the calibration procedures.
Format :cal:prot:code '<password>'
Parameter Up to a 8-character string including letters and numbers.
Description The :CODE command sends the password and enables calibration when per-
forming these procedures via remote. The correct password must be sent to
the unit before sending any other calibration command. The default remote
password is KI002430.
Note • The :CODE command should be sent only once before performing
calibration. Do not send :CODE before each calibration step.
• To change the code, first send the present code, then send the new code.
• The password parameter must be enclosed in single quotes.
• If you change the first two characters of the password to something other
than “KI”, you will not be able to unlock calibration from the front panel.
Example :CAL:PROT:CODE 'KI002430' Send default code of KI002430.
:COUNT?
(:CALibration:PROTected:COUNT?)
Purpose To request the number of times the Model 2430 has been calibrated.
Format :cal:prot:count?
Response Number of times calibrated.
Description The :COUNT? query may be used to determine the total number of times the
Model 2430 has been calibrated.
Example :CAL:PROT:COUNT? Request calibration count.
:LOCK
(:CALibration:PROTected:LOCK)
Purpose To lock out calibration.
Format :cal:prot:lock
Query :cal:prot:lock?
Response 0 Calibration unlocked
1 Calibration locked