7.11
Section 7
Electrical System and Components
7
9 or 15 amp Battery Charging System
Ground-to-Kill Lead
Violet
White
S
B
R
A
M
Key Switch
Optional Oil Sentry™
Indicator Light
Battery
Optional
Fuse
Green
Optional Oil Sentry™
Switch (Indicator)
Optional Oil Sentry™
Switch (Shutdown)
Red
Green
Engine
Connector
B+
Rectifier-
Regulator
AC
AC
Ignition
Module
Spark
Plug
Flywheel
Figure 7-9. 9 or 15 amp Regulated Battery Charging System.
Stator
Optional
Fuel
Solenoid
Bendix Starter
Starter Solenoid
Not For Resale
www.SmallEngineDiscount.com