11-4 82E-5 – 98E-5 SERIES
11. ELECTRIC WIRING
11.2 Precaution on Electric Wiring
11.2.1 Alternator
In the cases listed below the warranty shall not be deemed to apply. Please be sure to read these conditions
carefully when planning to use it with other equipment. Also be certain to give appropriate guidance on usage to
the user.
(1) When the battery cable can be connected backwards
The alternator diode will be damaged and recharging made impossible if the plus and minus ends of the
battery cable are confused. The stator coil will also be burned as a result. To prevent this, supply the user
with a cable of such a length or structure that the plus and minus ends cannot be confused. Also warn the
user not to connect the cable backwards.
(2) When charging output voltage is used for control purposes
The engine speed at starting is not proportional to the output voltage of the alternator, so this output voltage
must not be used for any control systems. It is especially wrong to use it for the control signal of the safety
relay for cutting the starting motor because this will damage the starting motor and cause engine starting
failure.
(3) When the L line is used for control purposes
Consult with Komatsu first before connecting any load other than the charge lamp to the L line. Damage to
the alternator and related equipment will not be warranted without such prior consultation.
(4) Non-use of the Komatsu wiring diagram
Use without prior consultation of any wiring diagram other than that provided by Komatsu removes any
breakdown of any electrical equipment from the warranty.
(5) Regarding lamp control
Once the charge lamp goes out after the start of charging, it does not come on again even if the engine
speed falls and charging is insufficient. The lamp will not light again if the charging circuit is normal. The
lamp only comes on during operation if the alternator itself is broken or the drive V-belt breaks. However,
when an LED is used for the charge lamp, the LED will shine faintly even during normal operation. This is
due to the control system for the alternator lamp and is not an abnormality.
(6) Use of a non-specified V-belt
Use of a non-specified V-belt will cause inadequate charging and shorten the life of the belt. Use a belt of
the specified type.
(7) Direct high pressure washing is prohibited
Water will enter the brush if the alternator is washed directly at high pressure, causing inadequate charging.
Warn users not to use direct, high-pressure washing.
(8) Adhesion of agricultural and other chemicals (direct contact or airborne)
Adhesion of agricultural and other chemicals, especially those with high sulfur content, to the IC regulator
corrodes the conductor on the substrate, leading to over-charging (battery boiling) and charging malfunc-
tions. Consult with Komatsu prior to using the engine in such an environment. Use without prior consultation
removes any breakdown from the warranty.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Komatsu 82E Series and is the answer not in the manual?

Komatsu 82E Series Specifications

General IconGeneral
BrandKomatsu
Model82E Series
CategoryEngine
LanguageEnglish

Related product manuals