PRECAUTIONS TO BE TAKEN DURING MAINTENANCE
46
2.8.13 PRECAUTIONS CONCERNING THE
BATTERY AND THE ALTERNATOR
2.8.14 PRECAUTIONS CONCERNING THE
STARTER
12
RWA01370
REMOVAL
RWA19920
• When repairing the electrical system, disconnet the battery in
order to stop the flow of current.
• Disconnect first the negative earth cable (-) and then the
positive cable (+).
At the end of the operation, reconnect first the positive ca-
ble (+) and then the negative cable (-).
• If electrical welding operations are to be carried out on the ma-
chine, it is necessary to disconnect the battery and also the al-
ternator.
RWA04890
RWAA0850
RWAA0850
• Do not start the engine by tampering with the terminals of the
starter, since the machine may move.
• Sudden or accidental movements of the machine may cause
serious injuries or even death.