2-96
PC130/150LGP-6K ENG
15. LONG-TERM STORAGE
15.2 DURING STORAGE
If it is unavoidably necessary to carry out the rustpreventive op-
eration while the machine is indoors, open the doors and win-
dows to improve ventilation and prevent gas poisoning.
Operate the engine and move the machine for a short distance once
a month so that a new film of oil will be coated over movable parts and
component surfaces. At the same time, also charge the battery.
Also carry out cooler operation in the case of machines equipped
with an air conditioner.
15.3 AFTER STORAGE
NOTICE
If the machine is stored without carrying out the monthly rust
prevention operation, request your Komatsu distributor for service.
Carry out the following procedure when taking the machine out of
long-term storage.
Wipe off the grease from the hydraulic cylinder rods.
Add oil and grease to all places.
15.4 STARTING MACHINE AFTER LONG-TERM
STORAGE
When starting the machine after a long-term storage, first cancel the
automatic warming-up function as follows.
1. Turn the starting switch key to the ON position.
2. Turn the fuel control dial from the low idling (MIN) position to the full
(MAX) position, hold it there for 3 seconds, then return it to the low
idling (MIN) position and start the engine.
WARNING

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Komatsu PC130-6K 2001 and is the answer not in the manual?

Komatsu PC130-6K 2001 Specifications

General IconGeneral
BrandKomatsu
ModelPC130-6K 2001
CategoryExcavators
LanguageEnglish

Related product manuals