SERVICE PROCEDURE MAINTENANCE
4-26
CHECK AXLE CASE BREATHER 0.
WARNING
When cleaning the axle breather, apply the parking brake
and secure the front and rear frames with the safety bar.
Remove all mud and dirt from around the breather with a
brush.
After removing the mud or dirt from around the breather,
remove the breather, immerse it in cleaning fluid and clean it.
When cleaning the breather, clean the breathers at two places
(front and rear).
After removing the breather, take steps to prevent dirt or dust
from entering the mount.
CLEAN CONDENSER OF AIR CONDENSER 0.
WARNING
! Do not wash the condenser with a steam cleaner. There is danger that the condenser overheat.
! If high-pressure water hits your body directly or dirt is sent flying the high-pressure water, there is
danger of personal injury. Always wear protective glasses, dust mask, and other protective equip-
ment.
If there is mud or dust on the air conditioner condenser, clean it with water.
WASHING METHOD
1. Open top cover (1) at the front of the engine hood.
2. Move radiator sub tank (2) to make space so that air condi-
tioner condenser (3) can swing to the rear.
3. Remove 4 bolts (4) at the top of the condenser.
4. Using pin (5) at the bottom of the condenser as the fulcrum,
push over to the rear.
5. Washer with water from the top.
6. Install bolts (4), then install sub tank (2) to its original posi-
tion.