HANDLING LOAD METER ATTACHMENTS, OPTIONS
6-22
12.At this point, the amount remaining in the bucket (3.1 tons)
is subtracted from the target load for the next loading opera-
tion, and the result (8.9 tons) is displayed as the target load.
The amount remaining in the bucket is 3.1 tons.
12.0 - 3.1 = 8.9 tons, so 8.9 tons is displayed as the next
target load.
13.If the second loading operation is to be carried out without
using the load remaining in the bucket, press the load meter
cancel switch. The target load will return to the initial setting
(12 tons).
The target load is displayed as 12.0 tons.
METHOD OF SETTING TIME ON CLOCK 0.
(The time display is only available on machines equipped with the load meter)
1. Check that the normal service meter and time are displayed
on the character display.
2. Press the (&) of monitor panel selector switch 1 and display
“LOAD METER“.