Page #282 background image
HANDLING LOAD METER ATTACHMENTS, OPTIONS
6-20
SUBTRACTION FUNCTION 0.
The following explanation assumes that after setting the remain
mode, the target load is 12 tons as shown in the diagram on
the right and that B is selected as the type of material.
1. This is the first load.
The result of measuring the load in the bucket is 5.1 tons.
12.0 - 5.1 = 6.9, so the next target load is displayed as 6.9
tons.
2. When 15 seconds pass after measuring, the bucket load is
deleted and the load is displayed as 0.0 tons.
3. This is the second load.
The load in the bucket is 4.9 tons.
6.9 -4.9 = 2.0 tons, so the next target load is displayed as
2.0 tons.