CENTRAL LUBRICATION ATTACHMENTS, OPTIONS
6-44
CHANGING THE LUBRICATION INTERVAL TIMES 0.
The settings when shipping from factory are as follows:
Greasing interval: after 1 hour
Greasing time: 12 minutes.
Changes are written to the memory, and the LED indicators
extinguish.
9
Press for more than 2s
000 in display flashes
Automatically indicates first parameter
Example: „Pause in timer operation“
LED „Pause“ flashes
Press briefly
(confirm code)
1
2
Press briefly
Set new value
Example: 6.8 h = 6 h 48 min
3
4
Press briefly
(confirm new value)
Press briefly
5
6
Indicates next parameter
„Pump running time in timer mode“
LED „Contact“ flashes
Set new value
Example: 3 min
Pump running time 4 min
7
Confirm new value
Press for
more than 2s
Press briefly
Key DisplayStep
8
Pause time 1 h

Table of Contents