2PX/2PY
1-4-47
(2) Table of general classification
Error code Description
U00000 No response or busy after the set number of redials.
U00100 Transmission was interrupted by a press of the stop/clear key.
U00200 Reception was interrupted by a press of the stop/clear key.
U00300 Recording paper on the destination unit has run out during transmission.
U004XX A connection was made but interrupted during handshake with the receiver unit (refer to
1-4-49 U004XX error code table).
U006XX Communication was interrupted because of a machine problem (refer to 1-4-49 U006XX
error code table).
U00700 Communication was interrupted because of a problem in the destination unit.
U008XX A page transmission error occurred in G3 mode (refer to 1-4-49 U008XX error code
table).
U009XX A page reception error occurred in G3 mode (refer to 1-4-49 U009XX error code table).
U010XX Transmission in G3 mode was interrupted by a signal error (refer to 1-4-50 U010XX error
code table).
U011XX Reception in G3 mode was interrupted by a signal error (refer to 1-4-51 U011XX error
code table).
U01400 An invalid one-touch key was specified during communication.
U01500 A communication error occurred when calling in V.8 mode.
U01600 A communication error occurred when called in V.8 mode.
U017XX A communication error occurred before starting T.30 protocol during transmission in V.34
mode (refer to 1-4-52 U017XX error code table).
U018XX A communication error occurred before starting T.30 protocol during reception in V.34
mode (refer to 1-4-52 U018XX error code table).
U03000 No document was present in the destination unit when polling reception started.
U03200 In interoffice subaddress-based bulletin board reception, data was not stored in the box
specified by the destination unit.
U03300 In polling reception from a unit of our make, operation was interrupted due to a mismatch
in permit ID or telephone number. Or, in interoffice subaddress-based bulletin board
reception, operation was interrupted due to a mismatch in permit ID or telephone num-
ber.
U03400 Polling reception was interrupted because of a mismatch in individual numbers (destina-
tion unit is either of our make or by another manufacturer).
U03500 In interoffice subaddress-based bulletin board reception, the specified Subaddress confi-
dential box number was not registered in the destination unit.
U03600 An interoffice subaddress-based bulletin board reception was interrupted because of a
mismatch in the specified subaddress confidential box number.
U03700 Interoffice subaddress-based bulletin board reception failed because the destination unit
had no subaddress-based bulletin board transmission capability, or data was not stored
in any subaddress confidential box in the destination unit.
U04000 In interoffice subaddress-based transmission mode, the specified subaddress box num-
ber was not registered in the destination unit.