Page 12
I − APPLICATION
G21/GSR21 unit input range covers 40,000 through 100,000
Btuh. See specifications table.
G21/GSR21 models use the same cabinet size as the ex
istingG14/GSR14furnaceline.Allunitsinthe
G21/GSR21 series use direct drive blowers and accept
cooling coils in nominal tonnages up to 5 tons for the 80,
100. Consult the Engineering Handbook for proper sizing.
Slab filters are used for either bottom or side return air in
G21 models and top return air in GSR21 models.
II − UNIT COMPONENTS
A − Control Box (Figures 1 and 2)
The G21 control box is located below the air intake chamber.
40, 60 and 80 control boxes are designed to open over the
exhaust PVC line when the unit is set up for righthand dis
charge of exhaust. 100 control boxes are designed to open
over the exhaust PVC line when the unit is set up for lefthand
discharge of exhaust.
The GSR21 control box is located in the lower righthand
corner of the heating compartment in horizontal installa
tions and in the upper righthand corner of the heating
compartment in reverse flow applications.
GSR21Q CONTROL BOX
TRANSFORMER
T1
TERMINAL
STRIP
TB1
TERMINAL
BLOCK
TB2
DOOR INTERLOCK
SAFETY SWITCH
(S51)
INDOOR
BLOWER
RELAY (K3)
FAN TIMING CONTROL
(A28)
GSR21V CONTROL BOX
TRANSFORMER
T1
TERMINAL STRIP
TB1
TERMINAL BLOCK
TB2
FIGURE 1
GROUNDING LUG
GROUNDING LUG
DOOR INTERLOCK
SAFETY SWITCH
(S51)
ACCESSORY
RELAY K109
TERMINAL BLOCK TB2
TERMINAL
STRIP TB1
ACCESSORY
RELAY K109
TRANSFORMER
T1
G21V CONTROL BOX
FIGURE 2
G21Q CONTROL BOX
GROUNDING
LUG
GROUNDING
LUG
TRANSFORMER T1
INDOOR BLOWER
RELAY K3
TERMINAL
BLOCK
TB2
FAN TIMING CONTROL
(A28)
TERMINAL STRIP TB1
1 − Control Transformer T1
A transformer (T1) located inside the control box provides
power to the low voltage section of the unit. Transformers are
rated at 30VA for Q" models and 50VA for V" models with a
120V primary and 24V secondary.
2 − Transformer Fuse F1
Transformer T1 is protected by a fuse F1. See table 1 for fuse
ratings. The fuse is located on the TB1 terminal strip.
TRANSFORMER FUSE
F1
TABLE 1
APPLICATION FUSE RATING
V" MODELS
Q" MODELS
3 AMP MDX SLOW BLOW
2 AMP AGC FAST BLOW