10 Parameter reference
10.2 Parameter list | C00223
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00223
C00224
C00225
C00226
C00227
Parameter | Name:
C00223 | L_PCTRL_1: Tn
Data type: UNSIGNED_16
Index: 24352
d
= 5F20
h
FB L_PCTRL_1: Reset time Tn for the PID process controller
Setting range (min. value | unit | max. value) Lenze setting
20 ms 6000 400 ms
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00224 | L_PCTRL_1: Kd
Data type: UNSIGNED_16
Index: 24351
d
= 5F1F
h
FB L_PCTRL_1: Derivative-action coefficient Kd for the PID process controller
Setting range (min. value | unit | max. value) Lenze setting
0.0 5.0 0.0
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10
Parameter | Name:
C00225 | L_PCTRL_1: MaxLimit
Data type: INTEGER_16
Index: 24350
d
= 5F1E
h
FB L_PCTRL_1: Maximum output value of the PID process controller
Setting range (min. value | unit | max. value) Lenze setting
-199.9 % 199.9 199.9 %
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00226 | L_PCTRL_1: MinLimit
Data type: INTEGER_16
Index: 24349
d
= 5F1D
h
FB L_PCTRL_1: Minimum output value of the PID process controller
Setting range (min. value | unit | max. value) Lenze setting
-199.9 % 199.9 -199.9 %
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00227 | L_PCTRL_1: Acceleration time
Data type: UNSIGNED_32
Index: 24348
d
= 5F1C
h
FB L_PCTRL_1: Acceleration time for the output value of the PID process controller
Setting range (min. value | unit | max. value) Lenze setting
0.0 s 999.9 0.1 s
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000

Table of Contents

Other manuals for Lenze 8400 BaseLine C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 BaseLine C and is the answer not in the manual?

Lenze 8400 BaseLine C Specifications

General IconGeneral
BrandLenze
Model8400 BaseLine C
CategoryInverter
LanguageEnglish

Related product manuals