4 Device control (DCTRL)
4.2 Device states
60
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2.7 Trouble
In the "Trouble" device state
is the controller if monitoring has caused a "Trouble" error response.
the motor has no torque (is coasting) due to the inhibit of the inverter.
Depending on certain conditions a state change takes place based on the "Trouble" device state.
Related topics:
Process data assignment for control via CAN
( 137)
Basics on error handling in the controller
( 145)
Error messages of the operating system
( 156)
LED DRIVE READY LED DRIVE ERROR Display in C137 Display in status word 1 (C150)
Bit 11 Bit 10 Bit 9 Bit 8
OFF Trouble 0111
Note!
The "Trouble" device state is automatically abandoned if the error cause has been remo-
ved.
If in C142
the "Inhibit at trouble" auto-start option is activated , an explicit deactivation
of the controller inhibit is required for leaving the state.
Change condition Changeover to the device state
The error cause is no longer active. ReadyToSwitchON
Control bit "EnableOperation" in control word wCANControl = "1"
AND terminal RFR = HIGH level (controller enable)
AND the message has been cancelled.
OperationEnabled
Control bit "EnableOperation" in control word wCANControl = "0"
OR terminal RFR = LOW level (controller inhibit)
AND the message has been cancelled.
SwitchedON

Table of Contents

Other manuals for Lenze 8400 BaseLine C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 BaseLine C and is the answer not in the manual?

Lenze 8400 BaseLine C Specifications

General IconGeneral
BrandLenze
Model8400 BaseLine C
CategoryInverter
LanguageEnglish

Related product manuals