Basic units in the power range 0.25 ... 2.2 kW
Relay output connection
6
Basic unit wiring
6.4
6.4.5
L
6.4-7
EDS82EV903-1.0-11/2002
6.4.5 Relay output connection
78200vec013
Fig. 6.4-5 Relay connection 0.25 ... 11 kW
Function Relay position
set
Message
(Lenze setting)
Technical data
X1.2/K11 Relay output
normally-closed contact
open TRIP
X1.2/K12 Mid position contact
C 250
3
X1.2/K14 Relay output -
normally-open contact
closed TRIP
...
.
PES HF-shield end by PE connection through shield bracket.
)
))
) Note!
l For switching the control signals use shielded cables and
establish an HF shield termination by PE connection.
l For mains potential switching unshielded cables are sufficient.
l The service life of the relay depends on the type of load (ohmic,
inductive or capacitive) and the value of the switching capacity.
l The output message can be changed under C0008 or C0415/1.
(
((
( Stop!
If you control a holding brake at the motor with the relay output, a
spark suppressor must be used in case of DC switching:
l Universal spark suppressor for 24 V DC brake,
l 6-pole Lenze brake rectifier for 180 V/205 V DC brake.