10.8.3 Digital setpoints via frequency input
It is possible to configure the digital inputs E1 and E2 of the standard I/O or
application I/O as frequency input. This enables you to select a digital frequency
as setpoint or actual value:
l For operation with standard I/O
– single-tracked: 0 ... 10 kHz at X3/E1
– two-tracked: 0 ... 1 kHz at X3/E1 and X3/E2
l For operation with application I/O
– single-tracked: 0 ... 100 kHz at X3/E1
– two-tracked: 0 ...100 kHz at X3/E1 and X3/E2
Codes for parameter setting
Code Possible settings IMPORTANT
No. Name Lenze Selection
C0425* Configuration 2
f
r
∆f
min
t f
max
• f
r
= Normalisation frequency ^ 10.8-9
v
frequency input
0 100 Hz 1/200 1s 300 Hz
–f
r
corresponds to C0011
single trac
X3
E1
1 1kHz 1/200 100 msec 3kHz
•
f
min
= Resolut ion
2 10 kHz 1/200 10 msec 10 kHz
• t=
canning rate
3 10 kHz 1/1000 50 msec 10 kHz
higher the dynamic response.
4 10 kHz 1/10000 500 ms 10 kHz
.
• f
max
= Maximum frequency which can
5(A) 102.4 kHz 1/400 2msec 102.4 kHz
be processe d i ndependently o f C0425
6(A) 102.4 kHz 1/1000 5msec 102.4 kHz
Set C0425 that the frequency coming
7(A) 102.4 kHz 1/2000 10 msec 102.4 kHz
max
•
ctivate fre
uenc
in
ut with C0410
24
=1
Configuration
10 100 Hz 1/200 1s 300 Hz
• Adjust frequency input under C0426 and
frequency input two
11 1kHz 1/200 100 msec 3kHz
C0427
trac
sX3
E1, X3
E2
12 (A ) 10 kHz 1/200 10 msec 10 kHz
13 (A ) 10 kHz 1/1000 50 msec 10 kHz
14 (A ) 10 kHz 1/10000 500 ms 10 k Hz
15 (A ) 102.4 kHz 1/400 2msec 102.4 k Hz
16 (A ) 102.4 kHz 1/1000 5msec 102.4 kHz
17 (A ) 102.4 kHz 1/2000 10 msec 102.4 k Hz
C0426* Gain frequenc y
input X3/E1, X3/E2
(A) (DFIN1-GAIN)
100 -1500.0 {0.1 %} 1500.0
C0426 =
f
N
â‹… p
z
â‹… C0011
â‹… 100 %
• f
r
= Normalisation frequency f rom
C0425
• p = Number of pole pairs of the motor
• z = Number of increments per revolution
of the encoder
• C0011 = Maximum output frequency
(corresponds to maximum process
speed of the motor)
C0427* Offset frequency
input X3/E1, X3/E2
(A) (DFIN1-OFFSET)
0.0 -100.0 {0.1 %} 100.0