Operation with rated power (normal operation)
Rated data for mains voltage 500 V
4
Technical data
4.3
4.3.3
L
4.3-13
EDS82EV903-1.0-11/2002
Typical motor p ower
P
r
[kW] 55 75 90 110
Three-phase
C asynchronous motor
(4 pole)
P
r
[hp] 74 100 120 148
8200 vector type With mains filter E82EV453K4B3xx E82EV553K4B3xx E82EV753K4B3xx E82EV903K4B3xx
Without mains filter E82EV453K4B2xx
1)
E82EV553K4B2xx
1)
E82EV753K4B2xx
1)
E82EV903K4B2xx
1)
Mains voltage U
mains
[V] 3/PE AC 320 V - 0 % ... 550 V + 0 % ; 45 Hz - 0 % ... 65 Hz + 0 %
Alternative DC supply U
DC
[V] DC 450 V - 0 % ... 775 V + 0 %
Data for op eration with 3/PE AC 500 V or DC 710 V
Rated mains current
without mains choke/mains f ilter I
mains
[A] - - - -
with mains choke/mains filter I
mains
[A] 80.0 100 135 165
Output power U, V, W S
r
[kVA] 73.9 91.4 124 149
Output power +U
G
,-U
G
2)
P
DC
[kW] 5.9 0 32.4 47.1
Rated output current at 1kHzsin
chopper frequency
2kHzsin I
r
[A]
5)
84 104 141 149
5)
4kHzsin
8kHzsin I
r
[A] 55
5)
71
5)
86
5)
94
5)
16 kHz sin
4)
I
r
[A] 39 55 60 63
1kHz
2kHz I
r
[A] 84 105 142 171
4kHz
8kHz I
r
[A] 84 105 142 162
16 kHz
4)
I
r
[A] 58 72 98 99
Max. permissible 1kHzsin
output current for 60 s
2kHzsin I
max
[A] 126 156 212 223
5)
at chopper frequency
3)
4kHzsin
8kHzsin I
max
[A] 82
5)
107
5)
169
5)
141
5)
16 kHz sin
4)
I
max
[A] 63 72 78 83
1kHz
2kHz I
max
[A] 126 157 213 256
4kHz
8kHz I
max
[A] 126 157 213 211
16 kHz
4)
I
max
[A] 75 94 128 130
Output voltage
without mains choke/mains f ilter U
M
[V] 3~ 0 ... V
mains
/ 0 ... 650 H z
with mains choke/mains filter U
M
[V] 3~ 0 ... approx. 94 % U
mains
/ 0 ... 650 H z
Power loss (operation with I
r8
) P
v
[W] 1100 1470 1960 2400
Required mains choke Type ELN3-0038H085 EL N3-0027H105 ELN3-0022H130 ELN3-0017H170
Dimensions
with mains f ilter H x W x D [mm] 510 x 340 x 375 591 x 340 x 375 680 x 450 x 375
without mains filter H x W x D [ mm] 510 x 340 x 285 591 x 340 x 285 680 x 450 x 285
Weight
with mains f ilter m[kg] 60 66 112
without mains filter m[kg] 34 37 59
Printed in bold = Data for operation at 8 kHz chopper frequency (Lenze setting)
1)
Operation only with mains choke or mains f ilter
2)
For operation with power-adapted motors additional power to be t aken from the DC bus
3)
Currents for periodic load change: 1 min overcurrent with I
max
and 2 min basic load with 75 % I
r
4)
Chopper frequency is reduced to 4 kHz if Ï‘
max
reaches - 5 °C
5)
Operation o nly with automatic chopper frequency reduction (C0144 = 1). Ensure not to e xceed the declared
current s.