Operation with increased rated power
Rated data for mains voltage 230 V
4
Technical data
4.4
4.4.1
L
4.4-1
EDS82EV903-1.0-11/2002
4.4 Operation with increased rated power
Under the application conditions described here the controller can be operated
in continuous operation with a motor of higher performance. The overload
capacity is reduced to 120 %.
Typical applications are pumps with square-law load characteristic or blowers.
)
))
) Note!
Operation with increased rated power is only permissible
l with the drive controllers mentioned
l within the mains voltage range mentioned
l with the chopper frequency mentioned
l with the prescribed fuses, cable cross-sections and mains
chokes
4.4.1 Rated data for mains voltage 230 V
Maximum motor power
T
h
r
e
e
p
h
a
s
e
A
C
a
s
y
n
c
h
r
o
n
o
u
s
m
o
t
o
r
P
r
[kW] 0.37 0.75 1.1 2.2
Three-phase
A
C asynchronous motor
(4 pole)
P
r
[hp] 0.5 1.0 1.5 3.0
8200 vector type EMC filter
integrated
E82EV251K2C0xx E82EV551K2C0xx
1)
E82EV751K2C0xx
1)
E82EV152K2C0xx
Without EMC filter E82EV251K2C2xx E82EV551K2C2xx
1)
E82EV751K2C2xx
1)
E82EV152K2C2xx
Mains voltage V
mains
[V] 1/N/PE AC 180 V - 0 % ... 264 V + 0 % ; 45 Hz - 0 % ... 65 Hz + 0 %
3/PE AC 100 V - 0 % ... 264 V + 0 % ; 45 Hz - 0 % ... 65 Hz + 0 %
Alternative DC supply U
DC
[V] not possible DC 140 V - 0 % ... 370 V + 0 %
Data for op eration with 1/N/PE (3 PE) AC 230 V or DC
325 V
1/N/PE 1/N/PE 3/PE 1/N/PE 3/PE 1/N/PE 3/PE
Rated mains current
without mains choke I
mains
[A] 4.1 - - - - 18.0 10.4
with mains choke I
mains
[A] 3.6 6.7 3.3 9.0 4.4 15.0 7.6
Output power U, V, W S
r
[kVA] 0.8 1.4 1.9 3.3
Output power +U
G
,-U
G
2)
P
DC
[kW] DC bus operation not
possible
0.1 0 0.4
Rated output current at 2kHzsin
I
[
A
]
2
0
3
6
4
8
8
4
R
a
t
e
d
o
u
t
p
u
t
c
u
r
r
e
n
t
a
t
chopper frequency
4kHzsin
I
r
[
A
] 2.0 3.6 4.8 8.4
Max. permissible
o
u
t
p
u
t
c
u
r
r
e
n
t
f
o
r
6
0
s
2kHzsin
I
[
A
]
2
5
4
5
6
0
1
0
5
output current for 60 s
at chopper frequency
3)
4kHzsin
I
max
[
A
] 2.5 4.5 6.0 10.5
Output voltage
without mains choke U
M
[V] 3~ 0 ... V
mains
/ 0 ... 650 H z
with mains choke U
M
[V] 3~ 0 ... approx. 94 % V
mains
/ 0 ... 650 H z
Power loss (operation with I
N24
) P
v
[W] 30 50 60 100
Required mains choke Type - ELN1-0500H005 ELN1-0500H009 E82ZL75132B -
Dimensions H x W x D [mm] 120 x 60 x 140 180 x 60 x 140 240 x 60 x 140
Weight m[kg] 0.8 1.2 1.6
1)
Operation only with mains choke
2)
For operation with power-adapted motors additional power to be t aken from the DC bus
3)
Currents for periodic load change: 1 min overcurrent with I
max
and 2 min basic load with 75 % I
r
Show/Hide Bookmarks

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze E82EV751K4C and is the answer not in the manual?

Lenze E82EV751K4C Specifications

General IconGeneral
BrandLenze
ModelE82EV751K4C
CategoryDC Drives
LanguageEnglish

Related product manuals