INFO: Infrared (local and link) port numbering can be found in the  section.
INFO: Only MMX4x2-HT200 model has TPS IR link.

Command and Response #infra #infrared
ç <ir_port>.CommandInjectionEnable=<ci_status>
æ <ir_port>.CommandInjectionEnable=<ci_status>
Parameters
Parameter Parameter description  
<ir_port> IR port number
S1, S2
IR inputs
D1, D2
IR outputs
<ci_status> 
true
Command injection mode is enabled
false
Command injection mode is disabled
Example
ç 
æ 
Changing Command Injection Port Number
Command and Response
ç <ir_port>.CommandInjectionPort=<port_no>
æ <ir_port>.CommandInjectionPort=<port_no>
Parameters
Parameter Parameter description  
<ir_port> IR port number
S1, S2
IR inputs
D1, D2
IR outputs
<port_no> TCP port number for
Command injection mode
Example
ç 
æ 

Command and Response
ç <ir_out>.EnableModulation=<modulation>
æ <ir_out>.EnableModulation=<modulation>
Parameters
Parameter Parameter description  
<ir_out> IR port number
D1, D2
IR outputs
<modulation> IR signal modulation
state
true
Signal modulation is enabled
false
Signal modulation is disabled
Example
ç 
æ 
Signal modulation is turned off on IR output (D1).
INFO: The default setting value is true (enabled).

Table of Contents

Other manuals for Lightware MMX4x2-HT200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lightware MMX4x2-HT200 and is the answer not in the manual?

Lightware MMX4x2-HT200 Specifications

General IconGeneral
BrandLightware
ModelMMX4x2-HT200
CategoryMatrix Switcher
LanguageEnglish

Related product manuals