EasyManuals Logo
Home>Lightware>Matrix Switcher>MMX4x2-HT200

Lightware MMX4x2-HT200 User Manual

Lightware MMX4x2-HT200
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #93 background imageLoading...
Page #93 background image
 MMX4x2 series – User's Manual 93

HDCP Setting (Output Port)
               
transmitted to a non-HDCP compliant display. See more information in the HDCP Management section.
Command and Response #hdcp
ç <out>.HdcpModeSetting=<hdcp_mode>
æ <out>.HdcpModeSetting=<hdcp_mode>
Parameters
Parameter Parameter description  
<hdcp_mode> HDCP encryption
setting on the output
port
0
Auto: The encryption is enabled on the output port if the
signal on the input port is encrypted.
1
Always: The outgoing signal is HDCP-encrypted.
Example
ç 
æ 
Test Pattern Generator
The output ports can send a special image towards the sink devices for testing purposes. The setting is
available on output ports with the parameters listed below. #nosyncscreen #testpattern
ATTENTION! The Mode can be set individually on each port, but the Clock source and the Pattern settings
are common on the optical and HDMI output ports (O1 and O2).
Test Pattern Generator Mode Setting
Command and Response
ç <out>.TpgMode=<tpg_mode>
æ <out>.TpgMode=<tpg_mode>
Parameters
Parameter Parameter description  
<tpg_mode> Test pattern generator
mode
0
Disabled: the test pattern is not displayed on the output.
1
Enabled: the test pattern is displayed on the output.
2
No signal mode: the test pattern is displayed if there is no
signal on the output port.
Example
ç 
æ 
The Clock Frequency of the Test Pattern
Command and Response
ç <out>.TpgClockSource=<tpg_clock>
æ <out>.TpgClockSource=<tpg_clock>
Parameters
Parameter Parameter description  
<tpg_clock> Clock frequency of
the test pattern signal
480 480p
576 576p
EXT External clock: coming from the actual TMDS source.
Example
ç 
æ 
Test Pattern
Command and Response
ç <out>.TpgPattern=<pattern>
æ <out>.TpgPattern=<pattern>
Parameters
The <pattern> can be: RED; GREEN; BLUE; BLACK; WHITE; RAMP; CHESS; BAR; CYCLE
Cycle setting means all the patterns are changed sequentially approx. every 2 seconds.
Example
ç 
æ 

Table of Contents

Other manuals for Lightware MMX4x2-HT200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lightware MMX4x2-HT200 and is the answer not in the manual?

Lightware MMX4x2-HT200 Specifications

General IconGeneral
BrandLightware
ModelMMX4x2-HT200
CategoryMatrix Switcher
LanguageEnglish

Related product manuals