8. Firmware Update MMX4x2 series – User's Manual 147

Update

Command
LightwareDeviceUpdaterV2_CLI.cmd update [options]
Options
Option Description Required?
-p or --package  yes
-i or --ip 
one of them is
mandatory
-n or --hostName 
-b or --backupFolder


optional
-f or --factoryDefault Apply factory reset during device update. Default: false optional
-r or --reportProgress Report update progress in percentage form. Default: false optional


at this command; see the The Built-in Miniweb section.
optional
ATTENTION! 
update command. In that case, there is no need to run the restore command after the update.
Example
C:\Program Files (x86)\Lightware\Lightware Device Updater V2>LightwareDeviceUpdaterV2_CLI.cmd update --ip
192.168.0.115 --package C:\Firmwares\tps-tx200_v1.6.4b2.lfp2 --reportProgress
c:\Program Files (x86)\Lightware\Lightware Device Updater V2>lib\jre\bin\java.exe -jar lib\ldu2.jar update --ip
192.168.0.115 --package d:\Firmware\4x2\Released\MMX4x2_v1.6.4b2.lfp2 --reportProgress
[2022-03-08 12:50:23.082] [ INFO] [ main] - Device IPs: [192.168.0.115]
[2022-03-08 12:50:26.591] [ INFO] [ main] - All selected devices are available over the network.
[2022-03-08 12:50:26.838] [ INFO] [ main] - All the selected devices are compatible with the specified
package.
[2022-03-08 12:50:27.662] [ INFO] [ 192.168.0.115] - Script parameters: deviceIp: 192.168.0.115, forceNoBackup:
false, factoryDefault: false, restoreFromBackup: true, backupFolder: C:/Users/laszlo.zsedenyi/.ldu2/backup,
skipPresetsAtRestore: false, ciscoRoomIntegration: false, updateVs100: false, uploadDefaultMiniWeb: false
[2022-03-08 12:50:27.670] [ INFO] [ 192.168.0.115] - Package version: 1.6.4b2
[2022-03-08 12:50:27.729] [ INFO] [ 192.168.0.115] - Login functionality is currently not enabled.
[2022-03-08 12:50:27.761] [ INFO] [ 192.168.0.115] - Creating backup of device settings...
[2022-03-08 12:50:30.646] [ INFO] [ 192.168.0.115] - Backup HTTP enable properties
[2022-03-08 12:50:31.860] [ INFO] [ProgressReporter] - Progress: 2%
[2022-03-08 12:50:32.739] [ INFO] [ 192.168.0.115] - HTTP and HTTP post have got enabled on port 80
[2022-03-08 12:50:32.950] [ INFO] [ 192.168.0.115] - No miniweb file is found on the device.
[2022-03-08 12:50:35.060] [ INFO] [ 192.168.0.115] - HTTP and HTTP post properties have got restored on port 80
[2022-03-08 12:50:36.862] [ INFO] [ProgressReporter] - Progress: 5%
[...]
The lines containing "ProgressReporter" can be enabled optionally. If it is enabled, the current state is

Restore

TIPS AND TRICKS: 

Command
LightwareDeviceUpdaterV2_CLI.cmd restore [options]
Options
Option Description Required?
-i or --ip 
one of them is
mandatory
-n or --hostName 
-b or --backupFile  yes
-k or --keepOriginalIp
Do not override the network settings of the device with the ones


Default: false
optional
ATTENTION! 
update command. In that case, there is no need to run the restore command after the update.
Example
C:\Program Files (x86)\Lightware\Lightware Device Updater V2>LightwareDeviceUpdaterV2_CLI.cmd restore --ip
192.168.0.115 --backupFile C:\mybackup.lw3 --keepOriginalIp
C:\Program Files (x86)\Lightware\Lightware Device Updater V2>lib\jre\bin\java.exe -jar lib\ldu2.jar restore --ip
192.168.0.115 --backupFile C:\mybackup.lw3 --keepOriginalIp
[2022-02-10 10:49:36.412] [ INFO] [ main] - Executing configuration restore...
[2021-02-10 10:49:36.425] [ INFO] [ main] - Device IPs: [192.168.1.12]
INFO:               
In

one for restoring is recommended.

Table of Contents

Other manuals for Lightware MMX4x2-HT200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lightware MMX4x2-HT200 and is the answer not in the manual?

Lightware MMX4x2-HT200 Specifications

General IconGeneral
BrandLightware
ModelMMX4x2-HT200
CategoryMatrix Switcher
LanguageEnglish

Related product manuals