Grove Published 11-22-2016, Control # 345-12 3-11
RT9130E-2 SERVICE MANUAL ELECTRICAL SYSTEM
6. Tag and disconnect the electrical leads from the
terminals on the starter.
7. Remove the bolts holding the starter to the mounting
pad. Remove the starter.
Installation
1. Place the starter on its mounting pad. Secure the starter
with the bolts.
2. Connect the electrical leads to the terminals as tagged
during removal.
3. Connect the batteries.
4. Install the ECM power fuse.
5. Turn the battery disconnect switch to the ON position.
6. Close the engine compartment.
Check
1. Try to start the engine. Verify the starter starts the
engine.
2. Start engine again, and listen for starter noises. Verify
there is no abnormal noise indicating the starter’s gear is
meshing improperly with the flywheel, that the starter’s
gear hasn’t disengaged from the flywheel after the
ignition switch is in the ignition (run) position, or some
other problem. Install starter properly as needed.
Battery Replacement
Removal
1. Ensure that the key switch has been off for 2 minutes.
2. Turn the battery disconnect switch to the OFF position.
3. Remove the ECM power fuse.
4. Remove negative battery cables.
5. Remove positive battery cables.
6. Tag and disconnect leads from the battery terminals
starting with the positive terminals.
7. Remove the nuts and washers from the bracket hold
down rods. Remove the hold down bracket.
8. Remove the batteries.
Installation
1. Place the batteries in the battery box.
2. Install the hold down bracket so it can hold down the
batteries. Secure the bracket to the bracket hold down
rods with nuts and washers.
3. Connect leads to the battery terminals starting with the
positive terminals.
4. Close the battery box cover.
5. Install the ECM power fuse.
6. Turn the battery disconnect switch to ON.
7. Verify replacement batteries work by starting crane’s
engine and operating various crane components.
Relay Panel Component Replacement
Accessory Relay
1. Turn the ignition switch to the OFF position.
2. Wait two minutes.
3. Turn the battery disconnect switch to the OFF position.
CAUTION
Possible Equipment Damage!
To avoid possible engine fault codes and undesirable
operation, ensure the keyswitch has been off two minutes
before disconnecting batteries.
Disconnect batteries if machine will be inactive for over 24
hours.