LUBRICATION RT9130E-2 SERVICE MANUAL
9-6 Published 11-22-2016, Control # 345-12
On all hoists with a check plug in the drum, the fill plug shall
be directly on top of the hoist, and the check plug level.
All grease fittings are SAE Standard unless otherwise
indicated. Grease non-sealed fittings until grease is seen
extruding from the fitting. One ounce (28 grams) of EP-MPG
equals one pump on a standard one pound (0.45 kg) grease
gun.
Over lubrication on non-sealed fittings will not harm the
fittings or components, but under lubrication will definitely
lead to a shorter lifetime.
On sealed U-joints, care must be exercised to prevent
rupturing seals. Fill only until expansion of the seals first
becomes visible.
Unless otherwise indicated, items not equipped with grease
fittings, such as linkages, pins, levers, etc., should be
lubricated with oil once a week. Motor oil, applied sparingly,
will provide the necessary lubrication and help prevent the
formation of rust. An Anti-Seize compound may be used if
rust has not formed, otherwise the component must be
cleaned first.
Grease fittings that are worn and will not hold the grease
gun, or those that have a stuck check ball, must be replaced.
Where wear pads are used, cycle the components and
relubricate to ensure complete lubrication of the entire wear
area.
CraneLUBE
Manitowoc highly recommends the use of CraneLUBE
lubricants to increase your crane’s reliability and
performance. Contact your Manitowoc Distributor for
information about the Manitowoc’s CraneLUBE lubrication
program.
Cummins Oil Registration List
Cummins has a program that lists engine oils that it has
tested to meet its engineering specifications. Listing of
recommended oils is on QuickServe® Online. Log on to
quickserve.cummins.com and login with a current username
and password or create a new account by selecting “Create
an Account” under information, choose Limited Owners Plan
and register. Once logged in, click on the “Service” Tab in the
top red bar, “Service Tools” mini-tab and “Oil Registration
Lists” link within the Service Tools list. This will load a list of
the different Cummins Engineering Specification numbers.
Select the one that applies to your engine to view the
registered oils.
Safety
To lubricate many of the locations the engine will need to be
started. After positioning areas of the unit for lubrication the
engine must be turned off and the moved areas stable before
approaching.
WARNING
Crushing Hazard!
Movement of the superstructure and the boom may
create a crushing and/or pinching hazard. Failure to
observe this warning could result in death or serious injury
if the message is ignored.

Table of Contents

Other manuals for Manitowoc Grove RT9130E-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove RT9130E-2 and is the answer not in the manual?

Manitowoc Grove RT9130E-2 Specifications

General IconGeneral
BrandManitowoc
ModelGrove RT9130E-2
CategoryConstruction Equipment
LanguageEnglish

Related product manuals