HOIST AND COUNTERWEIGHT RT9130E-2 SERVICE MANUAL
5-26 Published 11-22-2016, Control # 345-12
16. Slowly extend the counterweight removal cylinders (5)
(Figure 5-13) so the counterweight-to-hoist mounting
pins (12) (Figure 5-13) take the weight of the
counterweight (1) (Figure 5-13).
17. Connect the auxiliary hoist hydraulic lines and electrical
wires as tagged and disconnected earlier.
18. Remove the counterweight supports from the front of the
carrier.
Counterweight Stand Removal
1. Attach an adequate lifting device with slings to a
counterweight stand (1) (Figure 5-12).
2. Loosen jam nut (7) (Figure 5-12).
3. Rotate foot plates (5) (Figure 5-12) on the counterweight
stand (1) (Figure 5-12) away from the outrigger box (2)
(Figure 5-12).
4. Remove the counterweight stand (1) (Figure 5-12) to
carrier frame hitch pins (4) (Figure 5-12).
5. Using the lifting device with slings, remove the
counterweight stand (1) (Figure 5-12).
CAUTION
Do not power the counterweight into the counterweight-
to-hoist mounting pins.

Table of Contents

Other manuals for Manitowoc Grove RT9130E-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove RT9130E-2 and is the answer not in the manual?

Manitowoc Grove RT9130E-2 Specifications

General IconGeneral
BrandManitowoc
ModelGrove RT9130E-2
CategoryConstruction Equipment
LanguageEnglish

Related product manuals