Grove Published 11-22-2016, Control # 345-12 1-13
RT9130E-2 SERVICE MANUAL INTRODUCTION
1
Hydraulic Systems
Cleanliness
Contaminants in a hydraulic system affect operation and will
result in serious damage to the system components. Dirty
hydraulic systems are a major cause of component failures.
Keep the System Clean
When removing components of a hydraulic system, cover all
openings on both the component and the crane.
If evidence of foreign particles is found in the hydraulic
system, flush the system.
Disassemble and assemble hydraulic components on a
clean surface.
Clean all metal parts in a nonflammable cleaning fluid. Then
lubricate all components to aid in assembly.
Sealing Elements
Inspect all sealing elements (O-rings, gaskets, etc.) when
disassembling and assembling the hydraulic system
components. Installation of new elements is always
recommended.
Hydraulic Lines
When installing metal tubes, tighten all bolts finger-tight.
Then, in order, tighten the bolts at the rigid end, the
adjustable end, and the mounting brackets. After tubes are
mounted, install the hoses. Connect both ends of the hose
with all bolts finger-tight. Position the hose so it does not rub
on the machine or another hose and has a minimum of
bending and twisting. Tighten both couplings.
Due to manufacturing methods there is a natural curvature to
a hydraulic hose. The hose should be installed so any bend
is with this curvature.
Visual Inspection of Hoses and Fittings
1. Visually inspect hoses and fittings once a month or
every 250 hours for the following:
Leaks at hose fitting or in hose
Damaged, cut, or abraded cover
Exposed reinforcement
Kinked, crushed, flattened, or twisted hose
Hard, stiff, heat cracked, or charred hose
Blistered, soft, degraded, or loose cover
Cracked, damaged, or badly corroded fittings
Fitting slippage on hose
Other signs of significant deterioration
If any of the above conditions exist, evaluate hose
assemblies for correction or replacement. For replacement
of hose assemblies, refer to your Manitowoc Crane Care
Parts Manual.
DANGER
High Pressure/Temperature Hazard!
Exercise extreme care around pressurized hydraulic
systems. DO NOT work on a hydraulic system while it is in
operation or until all pressure is released.
Hydraulic oil is hot, it can cause severe burns.
Pressurized hydraulic oil can cause death or serious
injury.
Stay clear of all hydraulic oil leaks. Relieve system
pressure and use a piece of cardboard or paper to
check for leaks. Do not use your hands.
Fluid injected into skin must be surgically removed
within a few hours by a doctor familiar with this type of
injury or gangrene will result.
!

Table of Contents

Other manuals for Manitowoc Grove RT9130E-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove RT9130E-2 and is the answer not in the manual?

Manitowoc Grove RT9130E-2 Specifications

General IconGeneral
BrandManitowoc
ModelGrove RT9130E-2
CategoryConstruction Equipment
LanguageEnglish

Related product manuals