The following trigger modes are available:
Setting (GenICam)
Mode / Setting
(obsolete "Device
Specific")
Description
"TriggerSelector =
FrameStart"
"TriggerMode = Off"
Continuous Free running, no external trigger signal needed.
"TriggerSelector =
FrameStart"
"TriggerMode = On"
"TriggerSource =
Software"
"ExposureMode =
Timed"
To trigger one frame
execute the
TriggerSoftware@i
command then.
OnDemand
Image acquisition triggered by command (software
trigger).
"TriggerSelector =
AcquisitionActive"
"TriggerMode = On"
"TriggerSource =
<desired Line>"
"TriggerActivation
= LevelLow"
"ExposureMode =
Timed"
OnLowLevel
Start an exposure of a frame as long as the trigger
input is below the trigger threshold. (No
FrameTrigger!)
"TriggerSelector =
AcquisitionActive"
"TriggerMode = On"
"TriggerSource =
<desired Line>"
"TriggerActivation
= LevelHigh"
"ExposureMode =
Timed"
OnHighLevel
Start an exposure of a frame as long as the trigger
input is above the trigger threshold. (No
FrameTrigger!)
"TriggerSelector =
FrameStart"
"TriggerMode = On"
"TriggerSource =
<desired Line>"
"TriggerActivation
= FallingEdge"
"ExposureMode =
Timed"
OnFallingEdge
Each falling edge of trigger signal acquires one
image.
"TriggerSelector =
FrameStart"
"TriggerMode = On"
OnRisingEdge Each rising edge of trigger signal acquires one
image.
20 Appendix A.1 Pregius CMOS specific camera / sensor data
260