IGNITION
Page 2A-20 90-855347R1 JANUARY 1999
Ignition Module (Coil)
REMOVAL
1. Disconnect coil harness and spark plug lead.
2. Loosen the electrical mounting plate to gain access to the rear locknuts.
3. Remove module attaching bolts.
56141
a
c
b
d
e
f
g
h
i
j
b
a
b
c
b
d
j
i
h
g
f
e
a-Bolts (6) –Torque to 80 lb-in (9 Nm).
b-Ignition Coils (6)
c-Spacer – Place on Bolts between coils
d-Electrical Mounting Plate
e-Bolts (4) – Torque to 235 lb-in (27 Nm).
f-Washer
g-Rubber Grommet
h-Bushing
i-Washer
j-Locknut (6)
INSTALLATION
1. Fasten coils to electrical mounting plate as shown.
2. Reinstall electrical mounting plate.
3. Reconnect spark plug lead and coil harness.