Always check unit before applying power (see Sections 8-2 thru 8-11).
TM-246193 Page 63Invision 352 MPa
8-32. Front Panel/Display Board PC3 Test Point Values
PC3 Voltage Readings
a) Tolerance ±10% unless specified
b) Reference to circuit common
(lead 42) unless noted
Receptacle Pin Type Value
RC1 1 Output Output reference; 1 volt DC per 42.5 amperes of weld output when machine is under load; when machine
at idle, process set to MIG with .035 STL wire and ARGN CO2 gas selected; adjust control set to 10V
preset = 8.2V; adjust control set 38V preset = 9.4V
2 Output Voltage feedback; 1 volt DC per 10 volts DC of weld output
3 Input Current feedback; 1 volt DC per 100 amperes of weld output
4 Not Used
5 Output Output enable; 0 volts DC = ON, +12.5 volts DC = OFF
6 Not Used
7 Not Used
8 Not Used
9 Output Fan enable; +5 volts DC = fan on, 15 volts DC = fan off
10 Not Used
11 Input Main transformer overcurrent detect; +.7 volts DC = OK, +3.3 volts DC = T1 primary current = HELP 1
12 Not Used
13 Output +3.0 volts DC reference voltage for thermistors
14 GND Circuit common referenced to chassis
15 Input Secondary side thermistor return; +1.2 volts DC at 25
°
C thermistor temperature
16 GND Circuit common referenced to chassis
17 Input Primary side thermistor return; +1.2 volts DC at 25
°
C thermistor temperature
18 GND Circuit common referenced to chassis
19 Input Foldback; decreases weld output if input bus voltage drops, 0 volts = OK, +15 volts DC 15Khz pwm
squarewave = foldback
20 GND Circuit common referenced to chassis
21 Input +24 volts DC, unregulated DC voltage with respect to GND, power feed to front panel pcb
22 Input +24 volts DC, unregulated DC voltage with respect to GND, power feed to front panel pcb
23 Input 24 volts DC, unregulated DC voltage with respect to GND, power feed to front panel pcb
24 Input 24 volts DC, unregulated DC voltage with respect to GND, power feed to front panel pcb
RC2 1 Input Negative weld output terminal; used for output voltage feedback
2 Not Used
3 Input Positive weld output terminal; used for output voltage feedback

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miller Auto-Line Invision 352 MPa and is the answer not in the manual?

Miller Auto-Line Invision 352 MPa Specifications

General IconGeneral
BrandMiller
ModelAuto-Line Invision 352 MPa
CategoryInverter
LanguageEnglish

Related product manuals