2.Settingsusingthemainremotecontroller
Inthismenu,allparametersrequiredtorecordtheconsumedelectricalenergyandthedeliveredheat
energywhichisdisplayedonthemainremotecontrollercanbeset.Theparametersareanelectric
heatercapacity,supplypowerofwaterpumpandheatmeterpulse.
FollowtheproceduredescribedinGeneralOperationforthesetupoperation.
ForPump1,***canbealsosetbesidesthissetting.
Inthecase***isselected,thesystemacknowledges"factoryttedpump"isselected.
Energymonitorsettingsmenuscreen
<Running information>
Thisfunctionshowscurrenttemperatureandotherdataofmaincomponentparts
of both the indoor and outdoor units.
1.FromtheServicemenuhighlightRunninginformation.
2. Press CONFIRM.
3. Press F3 and F4 buttons to set the Ref. address. *1
4.Usethefunctionbuttonstoenterindexcodeforthecomponenttobeviewed.
(SeetheTable9-4-1forcomponentindexcodes.)
5. Press CONFIRM.
*1 For multiple outdoor units control system only.
<Thermistor reading>
Thisfunctionshowsthecurrentreadingsofthermistorslocatedonthewaterandrefrigerantcircuit
Thermistor Description Thermistor Description
TH1A Zone1 room temperature THW6 Zone1flowwatertemperature
TH1B Zone2 room temperature THW7 Zone1returnwatertemperature
TH2 Refrigerantreturntemperature THW8 Zone2flowwatertemperature
THW1 Waterflowtemperature THW9 Zone2returnwatertemperature
THW2 Water return temperature THWB1 Boilerflowwatertemperature
THW5 DHWtankwatertemperature THWB2 Boilerreturnwatertemperature
TH7 Ambient (outdoor) temperature
Externalinputsettingsmenuscreen
Demand control screen
Outdoorthermostatsettingscreen
<External input settings>
Demand control(IN4)
Outdoor thermostat (IN5)
Theselectionof“OFF”,whilstasignalisbeingsenttoIN4,forcefullystopsall
the heat source operations and the selection of “Boiler” stops operations of
heat pump and electric heater and performs boiler operation.
Theselectionof“Heater”,whilstasignalisbeingsenttoIN5,performs
electric-heater-only operation and the selection of “Boiler” performs boiler
operation.