8-TROUBLESHOOTING
8-TROUBLESHOOTING###_8_###
FAULTCODERESOLUTION
Errorcodeindex
NOTE:Ifyouhaveafaultcodeassociatedwitharedlightīashingandanaudiblealarm,shuttheunitdownandcall
yourdealerforsupport.Forafaultcodeassociatedwithayellowamberlight,recordthecodenumberandusethe
AuxOverridebuttontomovepastthisfaultcode.Ifthecodeappearsagain,contactyourdealerforsupport.
JOYNuāControlhandleerror
JOYNuappearsontheinstrumentpanel.Makesurethatthecontrolhandlesandtheauxiliarythumbwheelareinthe
neutralposition.IfJOYNucontinuestobedisplayedcontactyourdealerforsupport.
OPRPrāOperatorpresenceerror
OPRPrappearsontheinstrumentpanel.Makesurethatyouaresittingintheoperatorseat,theseatbeltisfully
engaged,andtherestraintbar(ifequipped)isinthedownposition.IfOPRPrcontinuestobedisplayedcontactyour
dealerforsupport.
CRKOnāHydraulicenableerror(EHmachinesonly)
CRKOnappearsontheinstrumentpanel.CRKOnindicatestheOPERATEbuttonisbeingpressedwhileattempting
tostartthemachine.Followthestartingprocedureasdescribedinthismanual.IfCRKOncontinuestobedisplayed
contactyourdealerforsupport.
Thefollowingisadisplayoferrorcodesandassociatedfunctions.
1000to1999(vehicleerrors)
Code
FunctionDescription
Code
FunctionDescription
1002
EngineCoolant
Temperature
HighTemperature1350HydraulicsEnable
SwitchImplausible
State
1004
HydraulicOilFilter
Restriction
FilterRestricted1511RightBrakeLight
Actuation
OpenCircuit
1009
HydraulicOil
Temperature
HighTemperature1512RightBrakeLight
Actuation
ShortCircuit
1014
ClusterSystem
Voltage
OverVoltage
1513RightBrakeLight
Actuation
ShortCircuitto
Ground
1015
ClusterSystem
Voltage
UnderVoltage1521
LeftBrakeLightActuationOpenCircuit
1025
LoadControlShortCircuit
1522
LeftBrakeLightActuationShortCircuitto
Ground
1030
LoadControlOpenCircuit
1523
LeftBrakeLightActuationShortCircuit
1041RPMMonitoring
OverSpeed
1531BackupAlarmActivation
OpenCircuit
1045FuelLevel
Monitoring
OpenCircuit
1532BackupAlarmActivation
ShortCircuitto
Ground
1201
HydraulicOilFilter
Restriction
OpenCircuit
1533BackupAlarmActivation
ShortCircuit
1202RPMMonitoring
OverSpeed
1901
PowerSupplySupplyVoltage
High
1203RPMMonitoring
Open/ShortCircuit
1903
PowerSupply
LowVoltage
1204
StartSequenceEngineStatePlausibility
Check
1904
PowerSupplyInputVoltageOut
ofRange
1205HydraulicEnable
ShortCircuittoPower
1905
PowerSupplySupplyVoltageOut
ofRange
1206
UCMConīægurationTimeout
1906
PowerSupplySupplyVoltageOut
ofRange
8-1